The functions linked to the second input can be activated also
by means of the programming wheel set on DOWN outside the
programming menu or by means of a remote control stored on
channel 2.
PLUG IN RECEIVER
City4 control unit is suitable for plugging in a Personal Pass
MR1 receiver having a high-sensitivity super-heterodyne
architecture.
WARNING: it is necessary to turn off the control unit
power before doing the operations mentioned here below. Pay
attention to the way you connect the removable modules.
MR1 module receiver is provided with 4 channels and each of
them is suitable for a command of City4 control unit:
CHANNEL 1
START
CHANNEL 2
PEDESTRIAN START
CHANNEL 3
STOP
CHANNEL 4
COURTESY LIGHT
WARNING: Before programming 4 channels and function
logics read carefully the instructions of MR1.
EXTERNAL AERIAL
We suggest to use the external aerial (model: ANS433 or
ANSGP433) in order to guarantee the maximal range.
Connect the antenna hot pole to terminal A2 of the control unit
and the braiding to terminal A1.
INTERFACE
The ADI (Additional Devices Interface) interface of the control
unit City4 allows the connection to V2 ELETTRONICA optional
modules. See V2 ELETTRONICA catalogue to check the ones
fitting this control unit.
WARNING: Please read the instructions of each single
module to install the optional modules.
CONTROL PANEL
When power is on, the control unit checks that display correctly
operates by switching on all segments for 1.5 sec. 8.8.8.8.
Firmware version, e.g. Pr I.0, will be viewed in the following 1.5
sec. Panel will be viewed upon completion of this test.
The control panel represents the physical status of the
terminal board contacts and of the program mode keys: if the
upper vertical segment is on, the contact is closed; if the lower
vertical segment is on, the contact is open (the picture above
shows the case of START, START P , STOP , FOTO, COSTA, FCA and
FCC inputs correctly connected with the gate closed).
25