MAINTENANCE
Table 2: Maintenance Schedule - Authorized Westinghouse Service Dealer Performed
Maintenance
Before Every
Item
Fuel Filter

ENGINE OIL MAINTENANCE

Engine Oil Specification
1. Only use the engine oil specified in Figure 26.
2. Only use 4-stroke/cycle engine oil. NEVER USE
2-STROKE/CYCLE OIL.
0°C
SAE 5W-30
SAE 10W-30
A
32°F
Figure 26 – Recommended Oil

Checking Engine Oil

NOTICE
Always maintain proper engine oil level. Failure to
maintain proper engine oil level could result in severe
damage to the engine and/or shorten the life of the
engine.
Always use the specified engine oil. Failure to use the
specified engine oil can cause accelerated wear
and/or shorten the life of the engine.
Engine oil level should be checked before every use.
1. Always operate or maintain the inverter on a flat
surface.
2. Stop engine if running.
3. Let engine sit and cool for several minutes (allow
crankcase pressure to equalize).
4. Remove the engine service panel to access the oil
fill/drain plug.
5. With a damp rag, clean around the oil fill/drain plug.
6. Remove the oil fill/drain plug (see Figure 27).
28
After First 20
Hours or First
Use
Month of Use
25°C
SAE 15W-40
C
B
80°F
After 50 Hours
After 100 Hours
of Use or Every
of Use or Every
3 Months
6 Months
Check/Clean
Figure 27 – Oil Fill/Drain Plug (WH1000i Shown)
NOTICE
Engine oil must always be checked and added when
the inverter is on a flat, level surface, or an inaccurate
reading may result, causing serious engine damage.
7. Check oil level:
When checking the engine oil, remove the oil fill/
drain plug.
The oil level is acceptable if oil is visible at the
bottom of the threads of the oil fill plug.
If oil level is low, add to the correct level using
the supplied oil fill bottle. Do not overfill the oil
crankcase.
Figure 28 – Checking Oil Level
After 300 Hours
of Use or Every
Year