Mounting The Cable Assembly - Abicor Binzel MB ERGO 14 Instructivo De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MB/RAB
4.2.2 PA liner

4.3 Mounting the cable assembly

6 Slide sharpened spiral wire liner through the cable hose up to the liner collet
and tighten the liner retention nut with wrench.
7 Screw in contact tip and install gas nozzle.
PA liners = for aluminium, copper, nickel and stainless steels.
1 Sharpen the front of the PA liner to approx. 40° with the ABICOR BINZEL
sharpener and slide PA liner through the cable hose until a noticeable
resistance is felt in the contact tip.
2 Slide forward the liner collet, O-ring and liner retention nut on the PA liner
and tighten the liner retention nut under compression.
3 Mark excess PA liner in front of the wire feed rollers and Cut the PA liner at
the mark with the ABICOR BINZEL cutter.
4 Sharpen the liner after cutting.
NOTICE
• For PA liners of outer diameter 4.00 mm, the capillary tube in the
adaptor kit must be replaced by a guide tube.
1 Connect Euro plug and adaptor kit at the wire feed unit and secure them
with the retention nut.
2 Properly mount the connections for water supply/return, shielding gas and
control line plug.
NOTICE
• Check the minimum coolant level of the cooling device.
• Make sure that the coolant supply and return have been installed
properly. Coolant supply = blue, Coolant return = red.
• Do not use any deionized or demineralized water as coolant or for
tightness or flow tests.
This may impair the service life of your welding torch.
• We recommend the use of ABICOR BINZEL series BTC coolant for
liquid-cooled welding torches.
4 Putting into operation
EN - 7

Publicidad

Tabla de contenido
loading

Tabla de contenido