Reloading Applicator (continued)
WARNING
!
Do not heat or expose 3M™
Scotch-Weld™ Polyurethane Reactive
(PUR) Easy 250 or 3M™ Scotch-Weld™
Polyurethane Reactive Adhesive to
temperatures or surfaces above 275°F
(135°C). Vapors of heated material
may be irritating to eyes and
respiratory tract and may cause
asthma-like symptoms in persons
previously sensitized to isocyanates.
WARNING
!
3M™ Scotch-Weld™ Polyurethane
Reactive (PUR) Easy 250 or 3M™
Scotch-Weld™ Polyurethane Reactive
Adhesive Cartridges should be
preheated or used in 3M™
Scotch-Weld™ Polyurethane Reactive
(PUR) Easy 250 Adhesive Preheater or
3M™ Scotch-Weld™ (PUR) Easy 250
Adhesive Applicator only. Do not
preheat 3M™ Scotch-Weld™
Polyurethane Reactive (PUR) Easy 250
or 3M™ Scotch-Weld™ Polyurethane
Reactive Adhesive Cartridges in ovens
or other heating devices or use in
other applicators. May cause
hazardous conditions.
IMPORTANT: For additional health and
safety information, see product label
and Material Safety Data Sheet for
Scotch-Weld Adhesive used.
Caution
!
Do not connect the applicator to air
supply with greater than 80 psi air
pressure. May cause hazardous
conditions or damage the applicator.
IMPORTANT: For disposal of adhesive or
adhesive components, please read and
follow information found on the selected
3M™ Scotch-Weld™ Polyurethane
Reactive (PUR) Easy 250 Adhesive MSDS.
12
3M™ Scotch-Weld™ Polyurethane Reactive (PUR) Easy 250 Adhesive Applicator User's Manual
13. Tighten applicator end cap to insure a positive seal by turning clockwise and follow
"Dispensing" procedure for trouble free operation.
Dispensing
1. Activate the trigger on the applicator for adhesive application. For best results, set
the air pressure at 80 PSI to start flow.
2. Adjust for desired adhesive flow by setting the air regulator between 30 PSI and 80 PSI.
Important: Allowing no more than 1/16" to 1/8" of the plastic disposable nozzle to
protrude from the Tip shroud will assure the adhesive will remain melted between
actuations.