Troubleshooting (continued)
Condition 2:
No or Low Adhesive Flow/
No Audible Air Leak
Caution
!
Do not connect the applicator to air
supply with greater than 80 psi air
pressure. May cause hazardous
conditions or damage the applicator.
IMPORTANT: For disposal of adhesive or
adhesive components, please read and
follow information found on the selected
3M™ Scotch-Weld™ Polyurethane
Reactive (PUR) Easy 250 Adhesive MSDS.
26
3M™ Scotch-Weld™ Polyurethane Reactive (PUR) Easy 250 Adhesive Applicator User's Manual
Conduct the following tests if there is NO audible air leak but the applicator heats.
1. Check air supply for a pinched line.
2. Remove applicator end cap by turning counterclockwise. Point the end cap away
from you and others in the work area, and pull trigger. A steady air stream
flowing from the pierce tube indicates air valve and air source are in working
order. Proceed to next step. If there is no air flow, proceed to page 28. step 8.
3. Replace and tighten end cap, turning it in a clockwise direction. Increases air
pressure to approximately 80 psi. If adhesive begins to flow, readjust to
desired pressure. If there is still no or low-adhesive flow, continue to next step.
© 3M 2014