PROHEAT II SERIES · AIR/WATER SYSTEM
When installing the machine outdoors, make sure not to place it under a steep roof
where too much rain water can fall on it.
The machine should not be placed 1.5 meters above or 3 meters below the water line.
If water from evaporator condensation appears during operation, the machine has an
opening on the side to evacuate the water.
Do not install the equipment in an acid or alkaline environment to avoid corrosion that
may affect the evaporator battery.
V5
.
V
V4
SYPHON
11.

ELECTRICAL CONNECTIONS

The electrical connection must be carried out by the fitter taking the following points into
account:
Please perform the connection according to the circuit diagram included in this
manual.
© FLUIDRA 2016 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
ENGLISH
V1
V3
V2
V1-V2-V3: By-pass valves
V4-V5: Adjustment valves
Pag: 36