NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
•Donotusethisheaterforheatinghumanlivingquarters.
•Useofdirect-firedheatersintheconstructionenvironmentcanresultinexposuretolevelsofCO,CO2,andNO2con-
sidered to be hazardous to health and potentially life threatening.
•Donotuseinunventilatedareas.
•KnowthesignsofCOandCO2poisoning.
•Headaches, stinging eyes
•Dizziness, disorientation
•Difficulty breathing, feels of being suffocated
•Properventilationairexchange(OSHA29CFR1926.57)tosupportcombustionandmaintainacceptableairqualityshall
beprovidedinaccordancewithOSHA29CFRPart1926.154,ANSIA10.10SafetyRequirementsforTemporaryandPor-
tableSpaceHeatingDevicesandEquipmentusedintheConstructionIndustryortheNaturalGasandPropaneInstalla-
tionCodesCSAB149.1.
•PeriodicallymonitorlevelsofCO,CO2andNO2existingattheconstructionsite–attheminimumatthestartof
theshiftandafter4hours.
•Provideventilationairexchange,eithernaturalormechanical,asrequiredtomaintainacceptableindoorairquality.
CO
CO
2
NO
2
(ShortTermExposureLimit=15minutes)
CO
CO
2
NO
2
•Ensurethattheflowofcombustionandventilationairexchangecannotbecomeobstructed.
•Asthebuilding'tightensup'duringtheconstructionphasesventilationmayneedtobeincreased.
Installationofthisapplianceataltitudesabove2000ft(610m)shallbeinaccordancewithlocalcodes,orintheabsenceof
localcodes,theNationalFuelGasCode,ANSIZ223.1/NFPA54,orNationalStandardofCanada,NaturalGasandPropane
InstallationCode,CSAB149.1
The heater has been shipped from the factory set up for operation on propane gas.
WARNING
AirQualityHazard
USA8-HrTimeweightedaverage
(OSHA29CFR1926.55AppA)
50 ppm
5000 ppm
USA–CeilingLimit
5 ppm
Gas-Fired Infra-Red Tank Top Heater
Canada8-hrtimeweightedaverage
WorkSafeBCOHSGuidelinesPart5.1
andOntarioWorkplacesReg833
25ppm
5000 ppm
3ppm(Reg833)
CanadaSTEL(15minutesReg833/1hour
WSBC)WorkSafeBCOHSGuidelinesPart
5.1andOntarioWorkplacesReg833
100 ppm
15000ppm(WSBC)
30000ppm(Reg833)
1.0ppm(WorkSafeBC)
5.0ppm(Reg833)
E-8
Operating Instructions and Owner's Manual