Operation Tips; Cooling Operation; Heating Operation - Electrolux EPI09LEIW Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

13
www.electrolux.com
operation.
Water is leaking from the indoor
unit.
The air switch or protection switch
often interrupts power supply.
Water or other liquid is splashed
into the unit.
Mains cord and mains plug are
overheated.

6. OPERATION TIPS

6.1. Cooling operation

Air conditioners absorb heat from indoor
and transmit the heat to the outdoor unit
in order to decrease the room
temperature. The cooling capacity will
increase or decrease according to the
outdoor temperature.
Anti-freezing function
COOL mode and in a low ambient
temperature, frost will be formed on the
heat exchanger of the indoor unit. If the
temperature of the heat exchanger
decreases below zero, the compressor
will stop operation to protect the unit.

6.2. Heating operation

Air conditioners absorb heat from
outdoor and transmit the heat to the
indoor unit in order to increase the room
temperature. The heating capacity will
increase or decrease according to the
outdoor temperature.
unit from the power supply and contact an
authorised service centre.
Immediately stop operation, disconnect the
unit from the power supply and contact an
authorised service centre.
Immediately stop operation, disconnect the
unit from the power supply and contact an
authorised service centre.
Immediately stop operation, disconnect the
unit from the power supply and contact an
authorised service centre.
Immediately stop operation, disconnect the
unit from the power supply and contact an
authorised service centre.
Defrosting
If the outdoor temperature is low and
the outdoor humidity is high, frost will
form on the outdoor unit during
extended operation. The heating
capacity will decrease. The unit may
stop operation during defrosting.
During defrosting, the fan motors of
the indoor unit and outdoor unit will
stop operation.
During defrosting, the indoor indicator
flashes and the outdoor unit may emit
vapour. This is normal operation to
remove frost from the heat exchanger
of the outdoor unit.
After defrosting, the heating operation
will resume automatically.
6.3. Refrigerant Leakage
Detection
With this new technology, the dipsplay
area will appear EC and the indication
lamps continue flashing when the
outdoorunit detects refrigerant leakage.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Epi12leiwEpi18leiwEpi24leiw

Tabla de contenido