Be sure that the drain hose is located
at the lowest side of the bundle.
Locating at the upper side can cause
drain pan to overflow inside the unit.
Because the condensed water from
rear of the indoor unit is gathered in
ponding box and is piped out of room.
Do not put anything else in the box.
Indoor Unit
Liquid pipe
Connecting
cable
Drain hose
Indoor unit installation
1. Pass the piping through the hole
in the wall.
2. Hook the indoor unit onto the upper
portion of installation plate (Engage
the indoor unit with the upper edge of
the installation plate). Ensure the
hooks are properly seated on the
installation plate by moving it in left
and right.
3. Piping can easily be made by lifting
the indoor unit with a cushioning
material between the indoor unit and
the wall. Get it out after finish piping.
4. Press the lower left and right side of
the unit against the installation plate
until hooks engages with the their
slots.
Piping
insulation
Gas pipe
7.5. Outdoor unit
Outdoor unit drain joint installation
The drain joint is slightly different
according to the different outdoor unit.
For the drain joint with the seal (Fig.A),
first fit the seal onto the drain joint, then
insert the drain joint into the base pan
hole of outdoor unit, rotate 90° to
securely assemble them.
To install drain joint as shown in Fig.B,
insert the drain joint into the base pan
hole of outdoor unit until it remains fixed
with a clicking sound. Connecting the
drain joint with an extension drain hose
(Locally purchased), in case of the water
draining off the outdoor unit during the
heating mode.
Drain jiont
Seal
Refrigerant pipe connection
Flaring
1. Cut a pipe with a pipe cutter.
2. Put flare nuts on pipe/tube having
completed burr removal and flare the
pipe.
3. Firmly hold copper pipe in a die in the
dimension shown in the table below.
Upper
hook
Mounting
plate
Cushio-
ning
material
Base pan hole of
outdoor unit