RIB B2 Serie Manual Del Usuario página 26

Ocultar thumbs Ver también para B2 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

G
B
and reverse the two phase wires (V1/2 and W1/2) of the relevant motor/s.
4 - Press the PROG button and hold it to CLOSE completely the gate. When RED LEDS DL5
and DL3 are on, the gate leaves are closing (with a phase shift of 2 seconds). Check
leaves swinging and the closing mechanical stopper position.
5 - After 2 seconds motor starting and for the next 10 seconds motor working, the torque
controls automatically activated. Set the motor torque by the TORQUE Trimmer/s which
varies the output voltage to the motor/s (turn clockwise to increase the torque).
6 - After other 10 seconds motor working, the low speed controls automatically activated
(DIP 15 ON). Set the motor low speed by the LOW SPEED Trimmer to select the gate leaf
low speed in approaching.
7 - Close completely the gate.
8 - Turn DIP1 to OFF position, LED DL1 turns off.
During Point C procedure, safety devices (photocells and safetystrip) are not active.
D - TIMES PROGRAMMING
N.B.: DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND
THEIR INTERVENTION STOPS PROGRAMMING (THE DL1 LED FROM
FLASHING REMAINS ON FIXED) AND THE BUZZER PLAYS FOR 10
SECONDS. TO REPEAT THE PROGRAMMING PROCEDURE POSITION
THE DIP 1 AND DIP 2 TO OFF, CLOSE THE GATE THROUGH
PROCEDURE «CHECKING THE DIRECTION OF MOTOR ROTATION» AND
REPEAT THE PROGRAMMING OF THE CHOICE.
N.B.: The deceleration is automatically determined during the times programming,
and is activated about 50÷60 cm before the end of opening or end of
closing.
- FOR 2 MOTORS - DIP 12 OFF
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG./RADIO/OPEN/START button => M1 opens.
4 - Reached the mechanical stopper in opening => after 1 second press the PROG./RADIO/
OPEN/START button to stop M1 and open M2.
5 - When the mechanical opening stopper has been reached => after 1 second press the
PROG./RADIO/OPEN/START button => M2 stops.
6 - Press the PROG./RADIO/OPEN/START button => M2 closes.
7 - After a few seconds press the PROG./RADIO/OPEN/START button => M1 closes and
determine the phase displacement between M2 and M1.
At the same time the LED DL1 will stop flashing, signaling the exit from the programming
procedure.
From this moment the safety devices or other gate commands will work normally (inversions,
stops, alarms, etc.).
8 - When the time is over, the gate stops.
9 - AT THE END OF PROGRAMMING, RESET THE DIP 2 IN OFF POSITION.
- FOR 2 MOTORS WITH ELECTRIC LIMIT SWITCHES - DIP 12 OFF AND DIP
14 ON
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG./RADIO/OPEN/START button => M1 opens.
When the opening limit switch LSO M1 is pressed, M1 stops and M2 opens.
When the opening limit switch LSO M2 is pressed. M2 stops.
4 - Press the PROG./RADIO/OPEN/START button => M2 closes.
5 - Press the PROG./RADIO/OPEN/START button => M1 closes and determine the phase
displacement between M2 and M1.
When the LSC M2 and LSC M1 limit switches are pressed, the motors are switched off.
At the same time the programming LED DL1 stops flashing, signaling the output from the
learning procedure.
From this moment the safety devices or other gate commands will work normally (inversions,
stops, alarms, etc.).
6 - AT THE END OF PROGRAMMING,
- FOR 2 MOTORS WITH ENCODER - DIP 12 OFF, DIP 14 OFF and DIP 17 ON.
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG./RADIO/OPEN/START button => M1 opens.
As M1 opening is complete, the encoder stops M1 and M2 opens.
As M2 opening is complete, the encoder stops M2.
4 - Press the PROG./RADIO/OPEN/START button => M2 closes.
Press the PROG./RADIO/OPEN/START button => M1 closes and determine the phase
RESET THE DIP 2 IN OFF POSITION.
displacement between M2 and M1.
At the same time the programming LED DL1 stops flashing, signaling the output from the
learning procedure.
From this moment the operation is automatic or step by step and therefore any intervention
of the safety devices or other commands will be interpreted as automatic or step by step
operation (inversions, stops, alarms, etc.).
5 - AT THE END OF PROGRAMMING,
- FOR 1 MOTOR - DIP12 ON
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG./RADIO/OPEN/START button => M1 opens.
4 - When the mechanical opening stopper is reached, after 1 second press the PROG./
RADIO/OPEN/START button => M1 stops.
5 - Press the PROG./RADIO/OPEN/START button => M1 closes.
At the same time the led DL1 will stop flashing signaling the exit from the programming
procedure.
From this moment the safety devices or other gate commands will work normally (inversions,
stops, alarms, etc.).
6 - When the time count is over, the gate stops.
7 - AT THE END OF PROGRAMMING, RESET THE DIP 2 IN OFF POSITION.
- FOR 1 MOTOR WITH ELECTRIC LIMIT SWITCHES - DIP 12 ON and DIP 14 ON
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG./RADIO/OPEN/START => M1 button. The M1 LSO opening limit switch
will stop M1.
4 - Press the PROG./RADIO/OPEN/START => M1 button to close. The LSC M1 limit switch
will stop M1.
At the same time the led DL1 will stop flashing signaling the exit from the learning procedure.
From this moment the safety devices or other gate commands will work normally (inversions,
stops, alarms, etc.).
5 - AT THE END OF PROGRAMMING, RESET THE DIP 2 IN OFF POSITION.
- FOR 1 MOTOR WITH ENCODER - DIP 12 ON, DIP 14 OFF and DIP 17 ON.
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG./RADIO/OPEN/START button => M1 opens.
As M1 opening is complete, the encoder stops M1
4 - Press the PROG./RADIO/OPEN/START button => M1 closes.
At the same time the programming LED DL1 stops flashing, signaling the output from the
learning procedure.
From this moment the operation is automatic or step by step and therefore any intervention
of the safety devices or other commands will be interpreted as automatic or step by step
operation (inversions, stops, alarms, etc.).
5 - AT THE END OF PROGRAMMING,
- PEDESTRIAN OPENING
The gate must be fully closed.
1 - Turn DIP2 to ON position => the LED DL1 starts blinking quickly.
2 - Immediately, turn also DIP1 to ON position, the LED DL1 starts blinking slowly.
3 - Press the pedestrian pushbutton (COM A+/PED.), motor M1 opens
4 - When the motor M1 leaf is opened enough for the pedestrian crossing, press the
pedestrian pushbutton to stop the travel (thus defining the opening stroke of motor M1).
5 - Press the pedestrian pushbutton (COM A+/PED.), M1 closes.
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
F - RADIO CODES PROGRAMMING PROCEDURE FOR TOTAL OPENING
(1000 CODES MAX) - with radio module ACG8069
ATTENTION: before storing the radio codes, use DIP 13 to select which transmitters to use:
DIP 13 OFF: SUN-PRO variable code transmitters can be memorized:
SUN-PRO 2CH 2-channel - red keys and white led cod. ACG6210
SUN-PRO 4CH 4-channel - red keys and white led cod. ACG6214
SUN-PROX 2CH 2-channel - red keys and yellow led cod. ACG6220
SUN-PROX 4CH 4-channel - red keys and yellow led cod. ACG6224
DIP 13 ON (default): You can store transmitters with fixed code SUN and MOON:
SUN 2CH 2-channel - blue keys and white led cod. ACG6052
SUN 4CH 4-channel - blue keys and white led cod. ACG6054
26
RESET THE DIP 2 IN OFF POSITION.
RESET THE DIP 2 IN OFF POSITION.

Publicidad