CEBORA S.p.A.
Even when the output voltage is selected on display P (led J lit), adjusting the "Arc Length Correction"
from the Robot Terminal makes it possible to change the value of the correction. In this case, the "Arc
Length" correction is temporarily (3 seconds) indicated by the led K lights and display P shows the value.
Once the 3 seconds have elapsed, the Control Panel returns to the previous state.
In Parameter Selection Internal mode, the value of the correction may be changed using the knob Q.
Even when the output voltage is selected on display P (led J lit), the value of the correction may be
changed by using the knob Q. In this case, the "Arc Length" correction is temporarily (3 seconds)
indicated by the led K lights and display P shows the value.
Once the 3 seconds have elapsed, the Control Panel returns to the previous state.
4.10.3
Led L - Inductance.
Indicates that an "Inductance" correction is in progress.
Display P shows the value (-9.9 to +9.9, default = 0).
A negative number indicates that the inductance is being reduced and the arc becomes harder; positive
indicates an increase in the inductance, and the arc becomes softer.
In Standard program mode, Pulsed arc program mode and Manual mode the value of the correction
may be changed by adjusting the "Inductance Correction" from the Robot Terminal.
Even when the output voltage is selected on display P (led J lit), by adjusting the "Inductance Correction"
from the Robot Terminal it is possible to change the value of the correction. In this case, the "Inductance"
correction is temporarily (3 seconds) indicated by the led K lights and display P shows the value.
Once the 3 seconds have elapsed, the Control Panel returns to the previous state.
GB
In Parameter Selection Internal mode, the value of the correction may be changed using the knob Q.
4.11

Knob Q.

Operative in Standard program mode, Pulsed arc program mode, Job mode, Parameter Selection
Internal mode and within the "Service Functions" (par. 6) and the "Second Functions" menu (par. 7).
In Standard program mode and Pulsed arc program mode it permits the temporary display (3
seconds) of the "Arc Length" correction on display P.
In Parameter selection internal mode, it adjusts the values indicated by the leds J, K and L (par. 4.10).
The value is shown on display P.
In Job mode, if the "Job number" selected = 0 (zero), it selects the "Job number" to be called up, shown
on display P.
In "Service Functions," it selects the "program number" or "Job number" to be called up, shown on
display P.
In the "Second Functions" menu, based on the function shown on display O, it selects the abbreviation:
OFF, OnC, OnA, On, nOP, PrG, ALL, visible on display P.
4.12
Led A - Globular position.
When lit, it signals that the pair of values for "Wire speed" and "Welding voltage" chosen for welding
may give unstable arcs and splatters.
4.13
Led F - Hold.
Activated at the end of each welding session.
When lit, it signals that the values shown on the displays O and P (normally Amperes and Volts) are
those used during welding. These values are saved at the end of each welding session.
4.14
Led G - Thermostat.
Signals that the temperature protection has been tripped on the Power Source.
4.15
Led H - Safety Function.
Signals the status of the lock function for all keys.
Only the commands included in group AY remain operative.
To activate the function, press the AO key and, while holding it down, press the I key. The led H lights to
indicate that the function is active (keys not operative).
To disable it, press the buttons AO + I again.
3.300.162-C