SECOND FUNCTIONS.

"Robot" function (rob).

7.1
Press the AO key and holding it down press the key E to enter the "Second Functions" menu.
Use knob N to select rob on display O; with knob Q select the status of the function, visible on display P:
OFF = not active;
On
= active.
Press the keys AO + E to exit the "Second Functions" menu, saving all current settings automatically.
With the "Robot" function disabled (rob OFF) the Control Panel maintains full management of the
welding system (except for the welding command, Arc-on signal, which must always be provided by the
Robot Terminal).
With the "Robot" function enabled (rob On), operation of the system passes to the Robot Terminal and
the Control Panel maintains partial operations, depending on the "Operating Mode" selected (par. 3.1).
With the "Robot" function enabled (rob On), if the Robot Interface is disconnected or not powered, on
the Control Panel the displays O and P read rob int flashing (Power Source - Robot communication
interrupted).
With the "Robot" function enabled (rob On) and the Robot Interface connected and powered, the system
is ready to operate and the condition is shown on the Control Panel by the flashing led AT (Power Source
- Robot communication active).
GB
7.2

Cooling Unit management (H2O).

Press the AO key and holding it down press the key E to enter the "Second Functions" menu.
Use knob N to select H2O on display O; with knob Q select the type of operation, shown on display P:
OFF = off (default);
OnC = always lit;
OnA = automatic start-up.
Press the keys AO + E to exit the "Second Functions" menu, saving all current settings automatically.
Upon Power Source start-up, the Cooling Unit starts running to place the liquid in the cooling circuit
under pressure. If the start command (Arc-on) does not arrive within 15 seconds, the unit stops.
The unit begins running with each start command (Arc-on), and stops 3 minutes after the start signal goes
away.
If the coolant pressure is too low, the Power Source delivers no current and the message H2O will appear,
flashing, on the display O.
7.3

Spot and stitch welding (SP).

Available starting with the firmware in release 6 for art. 287 and 13 for art. 289.
Operative in Standard program mode, Pulsed arc program mode and Manual mode.
Press the AO key and holding it down press the key E to enter the "Second Functions" menu.
Use knob N to select SP on display O; with knob Q select the status of the function, visible on display P:
OFF = not active;
On
= active.
With the function SP active, other parameters become available.
Use knob N to select tSP on display O; use knob Q to assign a value to the field tSP, visible on display P.
Use knob N to select tin on display O; use knob Q to assign a value to the field tin, visible on display P.
Press the keys AO + E to exit the "Second Functions" menu, saving all current settings automatically.
7.4

Automatic Hot Start (HSA).

Operative in Standard program mode, Pulsed arc program mode and Manual mode.
Press the AO key and holding it down press the key E to enter the "Second Functions" menu.
Use knob N to select HSA on display O; with knob Q select the status of the function, visible on display
P:
OFF = not active;
On
= active.
With the function HSA active, other parameters become available.
3.300.162-C
36
04/03/2016