Installation requirements
Gas and Electrical Service
• The black dots in the graphic below represent the recommended locations of the gas
inlet and power outlet. Existing utilites may be used if they do not interfere with the
range installation. Check local building codes for permissible gas-valve locations.
• An external manual shut-off valve must be installed between the gas inlet and range so
gas to the range can be shut off. Installation must allow:
• Access to the gas shut-off valve when the unit is installed.
• Access to the remote circuit breaker panel/fuse box, when the range is in place.
• The gas supply piping and shut-off valve, and the electrical junction box/receptacle
must be located so they do not interfere with the range when it is installed.
• The junction box and gas shut off valve must be located so that the range can be
pulled out for service while the appliance remains connected.
Power cord position
28
English
Install_NX9900R_PRORANGE_DOP36M96_DA_DG68-01106C-02_EN+MES+CFR.indb 28
Gas inlet position
B
A
Model
DOP36M96*
Power cord
A
9
/
'' (W) X 6
/
'' (H) (25.1 cm x 17.5 cm)
7
9
8
8
Gas inlet
B
17
/
" (W) X 5
/
'' (H) (45.5 cm x 13.8 cm)
15
3
16
8
2019-08-13
6:30:51