9- Troubleshooting - JF 40 MAXXIUM Manual Técnico De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9- Troubleshooting

Problems
Gathering drums don't pull
the material properly
The chopped material was
not correctly cuted it is
rended
Machine is stuffing
Belts are sliding
Machine vibrate excessively Unbalanced knives
34
Causes
Gathering drums springs
has little pressure
Razor's edge is not enough
Counter knife worked up
Razor's edge is not enough
Improper rotor rpm
Excess of material
Belts loose
Solution
Increase the springs
pressure
Sharpen razors
Invert or replace the counter
knife
Sharpen razors
Check and adjust rotation
according rotations table
Control better the feeding in
inlet tube
Stretch our belts
When sharpen the knives,
perform uniform sharpening
on all them
Weight the knives in a
precision balance to certify
that all them has the same
weight
When replace knives always
replace the complete set

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

50 maxxium60 maxxium

Tabla de contenido