Connecting An Earth Ground - Irritrol IBOC Plus Guía De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Note: Although the battery and the SPC-2 share the same input
terminals, only one power source can be connected to the IBOC
Plus at any given time. If using the SPC-2, connect the Orange
6-Volt (+) wire and Black negative (–) wire to the IBOC's battery
input terminals.
Figure 5
OR
DC Latching
Control Valves
3. By default, sensor operation is disabled for all automatic watering
programs. To enable operation of the sensor, refer to the "Rain
Sensor Operation" on page 7.
Note: Do not connect the rain switch directly to the valve
common wire. Refer to the installation instructions provided with
the rain sensor for additional information.

CONNECTING AN EARTH GROUND

A power surge is a sudden rise in voltage on the power main line. It is
then often followed by a drop in voltage as the power line equipment
tries to protect area users. A lightning strike on the power grid is the
most common cause of power surges and can be damaging to the
controller. Surge protection is built into the IBOC Plus terminal board
to help protect the controller from surge damage by shunting the
voltage to earth ground.
Installation Procedures
Solar Panel (optional)
Note: Refer to instructions supplied with solar panel for
installation procedure.
BATTERY
FOR SERVICE
RAIN SENSOR
VALVE COM
USE ONLY
INPUT GND
INPUT GND
INPUT GND
+
-
L
N
+
-
1
2
3
4
5
6
7
8
9
10
11
EARTH
GND
3
2
Valve Common
1
Rain Switch
(optional)
MV/
PUMP
12
DC Latching
Master Valve
(optional)
Earth Ground
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Systems iboc plus

Tabla de contenido