Direction Of Rotation - Speedaire 35WC53 Manual De Instrucciones De Operación Y Lista De Partes

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS (CONTINUED)

Direction of Rotation

NOTE: Improper rotation will result in reduced compressor
life.
The direction of rotation must be counterclockwise (as shown
by the arrow on the flywheel in Figure 7) while facing the
flywheel side of the pump. The motor nameplate will show
wiring information for counterclockwise rotation.
Figure 7 - Direction of rotation
The proper direction is very important. The direction of
rotation of 3 phase motors can be reversed by interchanging
any two motor-line leads. For single phase motors, refer to
the motor nameplate.
Lubrication
This unit contains no oil.
Before operating compressor, fill
to the center of the sight gauge (see Figure 8).
Using any other type of oil may
shorten pump life and damage
valves.
Recommended Oil (2 Options)
Single viscosity SAE 30 ISO100 nondetergent
compressor oil. Part number 1WG50 or 4ZF21.
10W30 synthetic oil such as Mobil 1
Oil Capacity
Approximately 4 quarts
Fill the pump with oil to the center of the sight gauge
using oil fill opening (see Figure 8).
through the breather cap opening as this may cause oil
to leak and spray out during operation.
NOTE: Some residual oil may still be in the pump from
factory testing leaving a thin coat on the sight gauge;
however, there is not enough oil to operate the unit.
®
or 1WG49.
Do NOT fill the pump
Oil Fill Plug
Figure 8
Oil Fill Plug
Oil Drain Plug
Sight Gauge
Oil Drain Plug
Full
Low
Breather Cap