OPERATING INSTRUCTIONS (CONTINUED)
Crankcase Breather
During severe operating conditions or initial start-up, some oil may accumulate at the crankcase breather
opening. This is normal and will diminish as the pump accumulates run time and the piston rings become fully
seated.
Draining Tank
Condensation must be drained from the tank daily. On Shop Air
Series models use manual tank drain (see Figure 10). Refer to
instructions provided with the automatic drain.
Figure 10 - Manual Tank Drain
13