Fagor Trans'therm ARTT-20 Instrucciones Generales Para Instalación, Uso Y Mantenimiento página 16

Armario de regeneracion;
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Armario de regeneración Trans therm
For use with the probe option (optional)
Remove the temperature sensor from its holder.
Insert it in a container or tray situated, by preference, in the centre of the trolley.
Close the door.
If you do not wish to use the temperature hold mode, you may remove the trays or
containers.
If you wish to leave the products inside the cupboard while holding the temperature,
stabilize at the holding temperature. Use of the timer is not necessary. You may use it as an
alarm.
TRACEABILITY MODULE (OPTIONAL) - See page 2
A: on/off indicator
B: on/off button
C: binding screw
EXCESS HUMIDITY EVACUATION VENT (OUTLET)
The vent is activated using a plastic button situated in the upper-left hand corner of the
painted top.
Pull to open
Push to close
The vent must be used for products producing too much humidity (frozen products) or
when reheating without a lid.
CLEANING
UNPLUG THE APPLIANCE FROM THE ELECTRIC SUPPLY
Wait until the unit is cool before cleaning
The exterior and interior can be cleaned using a low-pressure hose. Before cleaning the
outside, remove the traceability module and install the plastic cap on
Stainless steel: use a non-abrasive sponge and soapy water, liquid grease removers,
non-
chlorinated solvents, or aerosol products for stainless steel. Do not use chlorinated or
acidic products (bleach).
Control panel and top: use soapy water and a non-abrasive sponge.
SERVICE
BEFORE ALL SERVICING, UNPLUG THE APPLIANCE FROM THE ELECTRIC SUPPLY.
CHANGING THE POWER LEAD AND ANY OTHER MAINTENANCE WORK MUST BE
CARRIED OUT BY AN APPROVED AFTER SALES SERVICE.
Probe failure
In the event that the regulation probe or temperature probe should fail, the cabinet would
no longer operate and the following message would be displayed:
Display unit C : «def»
Display unit F : «1 » if regulation probe / «2» if temperature probe .