Installation
.
Voltage Designation
X
200-240
P*
380-415
18
Q
200-240
T*
200-240
X
200-240
P*
380-415
25
Q
200-240
T
200-240
Note: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
The X voltage is not compatible with
Note:
CE and/or electric heat models.
IMPORTANT: For machines with X
voltage: If input power is single-phase,
connect L1 to L1 of terminal block and L2
to L2 of terminal block. Leave L3
unconnected on the input terminal block. If
input power is three-phase, connect L1, L2
and L3 to L1, L2 and L3 of the terminal
block.
26
Cabinet Freestanding
Electrical Specifications
50-60
1 or
2 or
6/4
3
3
50-60
3
3
3
50-60
3
3
5
50-60
1
2
8
50-60
1 or
2 or
11/6
3
3
50-60
3
3
3
50-60
3
3
7
50-60
1
2
12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Standard
15
14
2x2.5
3x2.5
15
--
3x2.5
15
14
--
15
14
--
15
14
2x2.5
3x2.5
15
--
3x2.5
15
14
--
15
14
--
Electric Heat
--
--
--
12
15
--
3x2.5
18
20
12
31
35
8
--
--
--
12
15
--
3x2.5
18
20
12
31
35
8
F232060
--
--
--
--
--
--