Plumbing

All models require an adequate potable water supply and
a gravity drain. The recommendations for tubing are:
Water supply to be 3/8" OD.
Drain to be 3/4" OD.
Supply:
There is one water supply connection, a 3/8" male flare
at the back of the cabinet. Connect to cold potable water
that has adequate pressure.
Note: Using water supply tubing smaller than 3/8" will
cause severe operational issues.
Water Filters:
The water filters must flow at least 10 liters per minute
or they will cause severe operational issues. Check with
the filter manufacturer. When replacing a prior ice
Field Supplied
Water Filter
Potable Water
Source
machine, do NOT assume that the water flow capacity of the
filter will be adequate.
All Drain Tubing Material must be RIGID. Flexible tubing will
eventually cause a restricted drain.
Drain:
There is one gravity drain connection, a 3/4" FPT fitting at the
back of the cabinet. Use only RIGID TUBING. Flexible tubing
may be easily kinked or become cracked.
The drain tube must be vented at the back of the cabinet. Use a
45 cm high vent.
The drain for the ice machine and the ice storage bin must be
SEPARATE or the ice machine's drain water may run into the
bin and MELT THE ICE.
Insulation is recommended for the ice machine reservoir and bin
drains.
Follow all applicable codes
Refrigerant and
Electrical Lines
to Condenser
Bin Drain
9
Potable Water
Inlet - 3/8" Male
Flare
Vented Drain
Ice Machine
Drain
Floor Drain