Scotsman reserves the right to make design changes
and/or improvements at any time. Specifications and
designs are subject to change without notice.
Scotsman assumes no liability or responsibility of any
kind for products manufactured by Scotsman that have
been altered in any way, including the use of any parts
and/or other components not specifically approved by
Scotsman.
Pre-Installation
Other Applications:
Check Scotsman sales information for
recommendations regarding applications.
Do not place Air Cooled models where the noise from
the fan(s) will be objectionable.
Check the nameplate for electrical requirements. The
nameplate is located on the back of the ice machine.
While the model and serial number are on the
nameplate, a serial number plate is located at the front
of the machine, near the controller.
Note: Slope front bins must have an internal baffle.
Scotsman's BH360 has the required baffle. .

Location

Air cooled models take room temperature air in from
the left side and discharge warm air out the back. Do
not place them where the heat and noise will be
objectionable.
A 154 mm MINIMUM clearance between the back and
a wall and between the left side and a wall or another
product is required for the basic operation and service
of the air cooled model.
Note: A 154 mm side clearance with zero top
clearance will NOT provide enough air exchange
space for optimum performance. 300 mm side
clearance is required when there is no top clearance.
Air cooled models come equipped with a baffle that
can be used when the machine is installed in a corner.
The purpose of the baffle is to limit air recirculation.
This can occur in a corner when the hot air from the
back of the machine is re-drawn back into the machine
from the nearest side of the machine.
Install the air baffle as shown on the left rear corner
when a side wall and back wall are between 150 and
450 mm from the unit.
Plumbing - Air Cooled
PLUMBING CONNECTIONS MUST CONFORM TO
ALL APPLICABLE CODES
CONNECT TO POTABLE WATER SUPPLY ONLY
Water Inlet
Air Cooled Models:
All models require an adequate potable water supply
and a gravity drain. The recommendations for tubing
are:
Water supply to be 3/8" OD.
Drain to be 3/4" OD.
Note: When replacing a prior ice machine, do not take
a short cut and reuse the old inlet and drain system.
INSTALL A NEW SYSTEM.
Supply:
Air cooled models have 1 water supply connection, a
3/8" male flare or 3/4" GAS at the back of the cabinet.
Connect to cold potable water with adequate pressure.
Note: Using water supply tubing smaller than 3/8" will
cause severe operational issues.
Water Filters:
The water filters must flow at least 6,45 liters per
minute or they will cause severe operational issues.
Check with the filter manufacturer. When replacing a
prior ice machine, do NOT assume that the water flow
capacity of the filter will be adequate.
All Drain Tubing Material must be RIGID. Flexible
tubing will eventually cause a restricted drain.
Drain:
Air cooled models have 1 gravity drain connection, a
3/4" FPT fitting at the back of the cabinet. Use only
RIGID TUBING. Flexible tubing may be easily kinked
or become cracked.
The drain tube must be vented at the back of the
cabinet. Use a 45 cm high vent.
The ice storage bin will have a drain out the back or
base, depending upon the model.
The drain for the ice machine and the ice storage bin
must be SEPARATE or the ice machine's drain water
may run into the bin and MELT THE ICE.
3