Plumbing; Electrical; Final Check List - Scotsman CME506 Indicaciones Para El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Storage Bin:
Tip the storage bin on its back, using parts of the carton to
protect the exterior finish. Install the legs or casters into the
threaded holes in the bottom of the bin.
Note: Stacked applications may not use casters.
Turn the leg levelers all the way in preparation for leveling
later. Return the bin to the upright position, remove any
paper covering the bin gasket.
Ice Maker:
The machine is heavy, so the use of a mechanical lift is
recommended for lifting the machine high enough to install
on top of the bin. After the unit is on the bin, align it with
the back. Secure it to the bin with the two metal straps and 4
bolts provided.
FOR THE PLUMBER
PLUMBING CONNECTIONS MUST
CONFORM TO ALL APPLICABLE CODES
CONNECT TO POTABLE WATER SUPPLY ONLY
Water Inlet
Air Cooled Models: The recommended water supply is
clean, cold water. Use 3/8" O.D. copper tubing, connect to
the 3/8" male flare at the back of the cabinet. Install a hand
valve near the machine to control the water supply.
Water Cooled Models: A separate 3/8" O.D. copper line is
recommended, with a separate hand valve to control it. It is
connected to a 3/8" FPT condenser inlet at the back of the
cabinet.
Drains
Air Cooled Models: There is one 3/4" FPT drain at the back
of the cabinet, the drain line is of the gravity type, and a 3
cm per meter fall is an acceptable pitch for the drain tubing.
There should be a vent at the highest point of the drain line,
and the ideal drain receptacle would be a trapped and vented
floor drain. Use only 3/4" rigid tubing.
Water Cooled Models: In addition to the above mentioned
drain, a separate condenser drain must be installed. Connect
it to the 1/2" condenser drain connection at the back of the
cabinet.
Storage Bin: A separate gravity type drain needs to be run,
similar to the air cooled drain. Insulation of this drain line is
recommended.
FOR THE ELECTRICIAN
ELECTRICAL CONNECTIONS MUST
CONFORM TO ALL APPLICABLE CODES
The electrical power to the unit is supplied through the
junction box at the rear of the machine.
Check the nameplate (located on the back panel) for the
voltage requirements, and for the minimum circuit ampacity.
The machine requires a solid chassis to earth ground wire.
The ice maker should be connected to its own electrical
circuit so it would be individually fused. Voltage variation
must remain within design limitations, even under starting
conditions.
The electrical disconnect switch with fuse protection must
be a two pole type with a minimum of 3 mm between open
contacts.
After Utility Connections:
1. Level the bin left to right at the canopy; level the ice
machine reservoir front to back at the white plastic cover
next to the water pump. To level use the leg levelers on the
end of the legs.
2. Wash out the bin. If desired, the interior of the bin could
be sanitized.
3. Locate the ice scoop (if supplied) and have it available for
use when needed.

FINAL CHECK LIST

1. Is the ice system installed indoors in a location where the
air and water temperatures are controlled, and where they do
not exceed the design limitations?
2. Is there an electrical service disconnect within sight of the
installed machine? Has the voltage been checked, and
compared to nameplate requirements?
3. Have all the plumbing connections been made and
checked for leaks?
4. Has the machine and bin been leveled?
5. Is there a minimum of 150 mm clearance at the back, left
and right side of the machine for proper service access and
air circulation?
6. Is the water pressure a minimum of 1 bar?
7. Has the machine been secured to the bin?
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cme656Cme806

Tabla de contenido