2.2
Description of the electrical connection
230 Vac Neutral
230 Vac Phase
Signal light
M 1 Com
M 1 Open
M 1 Close
M 2 Com
M 2 Open 10
M 2 Close 11
LSC M2 12
LSO M2 13
LSC M1 14
LSO M1 15
Photocell A 16
START 17
24Vac 18
24Vac / 12Vac 19
12Vac Serrat. 20
STOP 21
PEDESTRIAN 22
Photocell B 23
Common 1 - 24
Antenna + 25
Light 26
Light 27
PhotoTEST 28
12Vac 29
24Vdc + 30
Common 24Vdc - 31
Connection of the VOLTAGE line
230 Volt Single-phase alternate current. The
control unit power supply line must always be
protected with a magnetothermal switch or a
pair of 5A fuses.
A diff erential switch is recommended but not
indispensable if one is already installed on the
plant.
1
230 Vac Power supply 50 Hz NEUTRAL
2
3
230 Vac Power supply 50 Hz PHASE
4
Outputs for LAMP (fl ashing light electronic card) or 230 Vac COURTESY LIGHT,
maximum power of the lamp 40 or 100W
5
6
Output for motor connection 1 COMMON pole
7
Output for motor connection 1 pole OPEN
8
Output for motor connection 1 pole CLOSE
9
Output for motor connection 2 COMMON pole
Output for motor connection 1 pole OPEN
Output for motor connection 1 pole CLOSE
Input Closing Limit Switches motor no.2
Input Opening Limit Switches motor no. 2
Input Closing Limit Switches motor no. 1
Input Opening Limit Switches motor no. 1
Input photocell A; working only by closing (see chapter 2.11)
Input command bi-stable START
Output for 24Vac
Output for electrical lock 12Vac 50Hz 1A
Output for electrical lock 12Vac 50Hz 1A
STOP input
Input for bi-stable function partial opening PEDESTRIAN
Input photocell B working in closing and in opening (see chap. 2.11)
Common for all inputs:
services, Security devices, coaxial antenna cable sock.
Input for antenna (antenna cable)
Contact for light (for fl ashing light without electronic card)
Contact for light (for fl ashing light without electronic card)
Output 24Vac TEST (see chapter 6)
Output 12Vac
Output 24Vdc +
Output 24Vdc - Common for inputs: services and safety
Connection of the MOTOR
Pay particular attention not to invert
the OPEN and CLOSE poles.
When in doubt as to the correct connection, if possible, ma-
nually position the automation at the midpoint of its stroke. Be
ready to stop the system using the STOP control!
To be sure that the opening is really "opening", try to block the
photocells: if the gate begins to close, the connection is incor-
rect and the motor OPEN and CLOSE wires must be inverted.