EB TECHNOLOGY START-S4XL Manual De Instrucciones página 26

Tabla de contenido

Publicidad

START-S4XL
2.11
Connection of the photocell
The photocell receiver contact must be:
- clean (insulated from power supply voltages)
- type N.C. (Normally closed)
If more than one pair of photocells is used, they
must be connected in series.
PHOTOCELLS A (only in closing mode) 24 Vac
Without TEST
12 13 14 15 16 17 18 19 20 21 22 23 23 24 25
RX
NC Contact
PHOTOCELLS B (both in closing and opening) 24 Vac
Without TEST
12 13 14 15 16 17 18 19 20 21 22 23 23 24 25
RX
NC Contact
With TEST
12 13 14 15 16 17 18 19 20 21 22 23 23 24 25
TX
With TEST
12 13 14 15 16 17 18 19 20 21 22 23 23 24 25
TX
The photocell TEST ensures that the automation only fun-
ctions when the photocells are functioning properly.
In fact, the control unit performs the test before each ope-
ning. If there is a photocell malfunction, the control unit
turns the fl ashing lights on for 5 seconds and the automa-
tion does not start.
RX
!
NC Contact
RX
NC Contact
!
-8-
Technical Manual
If the input PHOTO A is
not used put the DIP 5 C in ON
If the input PHOTO B is
not used put the DIP 7 C in ON
28 29 30 31
TX
28 29 30 31
TX

Hide quick links:

Publicidad

Tabla de contenido
loading