Installation Site Specifications / Installation

Warning! Mortal danger!
If the motor is to be installed with a metal supporting foot, then it must be
fastened insulated against the floor to avoid the transfer of spurious voltages
to the device and swimming pool water.
Warning! Risk of damage!
As the pumps are not self-priming, the installation must be under water level.
Make sure you take this into account during the installation planning phase.
4.1

Planning the pump pit

fig. 7: Cross-sectional view of the pump
pit
BWSP
Pool water level
L
Air valve
When planning a pump duct take into account:
1. Clear dimensions min. 600 x 600 x 600
2. Return connection min. 300 mm under the pool water level
3. Leakage water discharge pipe-end min. DN 40
4. Cooling air supply for the motor min. 2x DN 125. Minimum clearance of the motor
cooling air inlet to the wall = 200 mm.
5. Be sure to cover the pump pit if it is installed in the open air.
Warning! Mortal danger!
The mains power supply cable must be equipped with an all-pole separator
with a contact opening of 3 mm.
6. The position of the non-return air valve (L) must always be over the pool water level
(BWSP).
7. The position of the switchgear cabinet (S) must always be over the pool water level
(BWSP).
8. In case of leakage from the pump, a suitable water drainage must be provided!