Electrical connections three-phase current

fig. 28: Basic circuit diagram for 400/
230 V three-phase current
Protective measures:
fig. 29: Basic circuit diagram for 400/
230 V three-phase current
60
8238
8239
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
OPERATING INSTRUCTIONS
Mains voltage:
Mains power supply
connection cable:
Pump power supply cable:
Fuse:
B =
Control unit in the pool
M =
Motor of the circulation pump
N =
Mains power supply
(400/230 V 3 ~)
S =
Switchgear cabinet
Connection
cable,
HO7RNF, all further details required for
making connections can be found in
chapter 3.1.
An earth leakage circuit breaker
(nominal fault current £30 mA) must be
fitted to the mains power supply!
Important: Watch the order of the
terminal bridges!
See the inside of the terminal box lid or
enclosed circuit diagram. Please be sure
to observe instructions from the motor
manufacturer!
L
External conductor
N
Neutral conductor
400/230 V for
3 ~ current
5 x 2.5 mm²
4 x 2.5 mm²
16A passive
for
example,
C2 rondo
Version: 27200 - D