8.2

Face plate assembly overwintering

Remove the face plate assembly and store at room temperature.
8.3

Draining the pump

fig. 34
9

Maintenance and Repair

9.1

General

All work on the counter-current unit must be carried out only if the pump has been drained
and the control unit and pump motor have been disconnected from the mains and secured
against unintentional reconnection.
9.2

Maintenance

The counter-current unit is largely maintenance-free.
Make sure that all the parts of the counter-current unit are kept clean.
The gaskets on the motor shaft must be checked at regular intervals (at least once a
year) by a trained engineer. If necessary, they must be replaced by original spare parts.
9.3
Repairs
For miscellaneous repairs to the counter-current system please observe the
instructions for installation and start-up in this manual.
Use exclusively original spare parts when carrying out repairs to the counter-current
unit.
64
8326
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
OPERATING INSTRUCTIONS
07
O-Ring
11
Plug screw
Screw out the plug screw (11) and drain
the water.
Warning! Risk of damage!
Make sure that all the water runs off! Also
drain the pipework connected to the
pump, if any!
Then screw the plug screw (11) back in
again with a new O-ring (07).
When restarting please observe the
instructions in section 6.