OPERATING INSTRUCTIONS
Please observe:
The mains power connection must be a fixed connection.
Under no circumstances must there be any conducting connection between the metal
parts of the motor and the water.
An earth leakage circuit breaker (nominal fault current £ 30 mA) must be fitted to the
mains power connection.
At the marked connection terminal (at the foot of the motor or next to the terminal box)
an equalising potential with a cross-section of 10 mm² must be fitted.
5.2

Electrical connections AC

fig. 26
Protective measures:
fig. 27: Basic circuit diagram for 230 V
for 1 ~ AC
C2 rondo
Version: 27200 - D
Mains voltage
Mains power supply cable: 3 x 2.5 mm²
Pump power supply cable: 3 x 2.5 mm²
Fuse:
B =
M =
N =
S =
C
= Capacitor
B
Connection
HO7RNF, all further details required for
8236
making connections can be found in
chapter 3.1.
An earth leakage circuit breaker
(nominal fault current £30 mA) must be
fitted to the mains power supply!
Important: Watch the order of the
terminal bridges!
See the inside of the terminal box lid or
enclosed circuit diagram. Please be sure
to observe instructions from the motor
manufacturer!
L
N
8206
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
230 V for 1 ~ AC
16 A passive
Control unit in the pool
Motor of the circulation pump
Mains power supply
(230 V for 1~)
Switchgear cabinet
cable,
for
External conductor
Neutral conductor
example,
59