Mount the clamp ring (30) with the clamp gasket (39) and the hold-ring (62) to the pool wall
(J). The sealing contact faces must be clean and smooth.
Mount the housing (84) to the clamp ring (30) with the nuts (26) and distance washers (83).
Warning!
The housing (84) must be mounted so that the connection for the membrane
switch is at the top.
4.8
Mounting the installation kit / Wooden-liner pool
fig. 17
J
Pool wall
02
Switchgear cabinet
31
Switching tube
26
Nut
27
Distance washer
30
Clamp ring
39
Clamp gasket
Mount the hold-ring (67) with the clamp ring (68) to the pool wall.
Hang in the liner. Fasten the liner and the clamp gasket (39) together with the clamp ring
(30) and cut out the liner.
Mount the housing (84) to the clamp ring (30) with the nuts (26) and distance washers (83).
Warning!
The housing (84) must be mounted so that the connection for the membrane
switch is at the top.
54
8430
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
OPERATING INSTRUCTIONS
fig. 18: Detail from fig. 17
63
Countersunk screw
67
Clamp ring
68
Hold-ring
83
Distance washer
84
Housing
85
Distance washer
8431
C2 rondo
Version: 27200 - D