Electrical Connection - Eaton Cooper Lighting PORTFOLIO LDSQ4 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.
Locking lever on quick disconnect must be latched as
shown (Figure 6.).
4.
Insert lens into lower trim with convex part facing down
(Figure 7 .).
5.
Insert LED engine into lower trim. Align LED engine
screw holes with lower trim screw slots (Figure 8.).
6.
Using provided thumb screws, securely attach lower
trim to LED engine (Figure 9.).
7 .
Install the LED engine and trim assembly by inserting
the torsion springs into the spring receivers located
inside the housing (Figure 10.).
Cleaning
To Clean Trims:
1.
Gently wipe with soft, clean, dry lint-free cloth to
remove dust.
2.
Wipe with mild detergent solution on a soft, clean cloth
to remove fingerprints and stains.
3.
Rinse with clean water and dry with soft, clean,dry
lint-free cloth.
Locking
Feature
Hook
Figure 6.

Electrical Connection

CAUTION
Make certain no bare wires are exposed outside of wire nut
connectors.
1.
Provide electrical service according to the "National
Electrical Code" or your local electrical code to the
junction box (located on the plasterframe). Supply wire
insulation must be rated for at least 90°C. The junction
box is rated for a maximum of 8 No. 12 AWG Branch
Circuit conductors and is also suitable for at least 90°C.
Installation Instructions – LDSQ4/LDSQ6 Commercial Recessed LED Rough-In
Powerplug®
Luminaire Disconnect
Locking Lever
Installation Instructions – LDSQ4/LDSQ6 Commercial Recessed LED Rough-In
705077INS
Figure 7.
Figure 8.
Figure 9.
Figure 10.
ADP140589 www.eaton.com
To Insert, Pinch
Torsion Springs
Torsion Spring
Receiver
3