Electrical Connections - Eaton Lumark Crosstour MAXX Instrucciones De Instalación

Ocultar thumbs Ver también para Lumark Crosstour MAXX:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions - Crosstour MAXX
INSTALLATION
BACK BOX INSTALLATION
1.
Unscrew door with Phillips screw driver. Remove door
from back box.
2.
Place inverted back box on solid surface. Using a 9/32"
bit, drill out the four mounting holes. (Figure 1.)
3.
Over Junction Box Wiring And Rear Entry Conduit
Installation: Loosen But DO NOT remove two screws
securing wire-way cover plate (Figure 2). Rotate
wire-way cover plate counterclockwise and remove
wire-way cover plate from opening. Do not remove the
wire-way cover plate for thru-branch wiring.
Use drill dimensions (Figure 3.) to mark drill location.
N
otee:
DO NOT use back box as the drill guide. Drill four
holes into wall surface. Secure back box to wall with
1/4" lag bolts and washers into anchors (anchors
supplied by others). Maximum allowable diameter
for lag bolt is 1/4" . Installer must apply silicone
compound around entire perimeter of the back box
where it mates to the mounting surface. This will
create a water-tight seal between the mounting
surface and the back box.

ELECTRICAL CONNECTIONS

4.
Over Junction Box: Make supply wiring connections to
the backside of the wire-way cover plate. Follow NEC
guidelines for wet location wiring (wire nuts supplied by
others). Ensure all wires are secured in the junction box
and re-install wire-way cover plate by rotating clockwise
into the screws. Tighten wire-way cover plate screws to
10 in-lbs. (Figure 2).
Thru-Branch Conduit: Remove the required 1/2" NPT
conduit plug(s). Apply sealing compound or Teflon
tape to liquid tight conduit fitting (supplied by others)
entering back box to create water tight seal. DO NOT
remove the wire-way cover plate (Figure 2). Remove
wire leads from the wire way cover plate by gently
pulling the wiring located in the black grommet toward
you. DO NOT remove black grommet from the
wire-way cover plate.
Back Conduit Entry: Remove the black grommet and
wires from the wire-way cover plate (DO NOT remove
circular gasket). Attach conduit to wire-way cover plate
with watertight connector. Re-install wire-way cover
plate by rotating clockwise into the screws. Tighten
wire-way cover plate screws to 10 in-lbs. (Figure 2).
5.
Secure door into lock hinges located at the top of the
back box (for down light illumination) (Figure 4). Utilize
Push-in connectors to make fixture-wiring connections
(see wiring diagrams).
2
EATON
IB514001EN
Installation instructions
Wall Gasket
Test Button
Back View of Back Box
Figure 1.
THIS SIDE IN FIXTURE
SEE INSTRUCTION FOR
CONDUIT APPLICATION
Wire-Way Cover Plate
THIS SIDE IN FIXTURE
Black
SEE INSTRUCTION FOR
CONDUIT APPLICATION
Grommet
Figure 2.
2-13/16"
2-1/2"
Access Outlet Box
Figure 3.
(4) Mounting
Holes
(2) Cover
Plate Screws
Black
Grommet
Wire-Way
Cover Plate
Push-in
Connectors
(Back view)
(4) Mounting
5-5/8"
Holes
5"
5"
Circular
Gasket

Publicidad

Tabla de contenido
loading

Tabla de contenido