DGCI-...
Electrical installation
DGCI-...
Measuring system
Protection class (measuring system
incl. housing and connections)
Electrical connection
Interface
Baud rate
Linearity
Resolution
Supply voltage
Current consumption
Temperature coefficient
CE symbol (see conformity
declaration)
www.festo.com
Fig. 32
Festo DGCI-...-Z6 1207b English
magnetostrictive, contactless, absolute
measuring, digital
IP67 (with correctly fitted connector socket with
cable)
5-pin M9 round plug
CAN as per ISO/DIS 11898
[Mbit/s]
1
< ±0.02 % F.S. (min. ±50 ìm)
[mm]
0.005
[V DC]
24 (±25 %)
[mA]
100 typical
< 15 ppm / °C
in accordance with EU EMC directive
45