DGCI-...
6
Commissioning
Commissioning the complete system
S
Slowly pressurize the complete system.
In this way you will prevent sudden
uncontrolled movements.
For slow start-up pressurization, use
safety start-up valve HEL.
Commissioning the DGCI
Warning
Uncontrolled fast moving parts can cause
injury to people in the vicinity of the DGCI.
S Make sure that:
– nobody can place his/her hand in the
path of the moveable mass (e.g. by
providing a protective grill)
– there are no objects within the position-
ing path.
It should not be possible to touch the
DGCI until the mass has come to a
complete stand.
Note
Special commissioning regulations apply to the electronic control of the DGCI.
S Complete the commissioning as described in the manuals for the controller.
Festo DGCI-...-Z6 1207b English
Fig. 16
Fig. 17
35