CMMOST-...-DION/DIOP
4.2
Electrical data
Control ports STO1/STO2 [X3]
Nominal voltage
Voltage range
Permissible residual ripple
Nominal current
Starting current
Input voltage thresholds (intermediate range undefined)
Logic 1
Logic 0
Activate STO function switching time
Deactivate STO function switching time
Maximum permissible pulse width
for 0 V test pulse with 24 V signal
for 24 V test pulse with 0 V signal
Minimum time between test pulses
for 0 V test pulse with 24 V signal
for 24 V test pulse with 0 V signal
Protective function
Tab. 11
Technical data: Electrical data for the inputs STO1 and STO2
Acknowledgment contact DIAG [X3]
Implementation
Max. voltage
Nominal current
Max. internal resistance (contact closed)
Residual current (contact open)
Switching time closing
Switching time opening
Galvanic isolation
Protective function
Tab. 12
Technical data: Electrical data of the acknowledgment contact
Festo – GDPC-CMMOST-EA-S1-Z6 – 1506c – English
[V DC] 24 (relative to 0 V at [X9] )
[V DC] 21.6 ... 28.8
[%]
5 (relative to nominal voltage 24 V)
[mA]
15
[mA]
200
[V DC] 18
[V DC] 5
2
[ms]
6
[ms]
[ms]
0.5
[ms]
5
[ms]
25
[ms]
25
Protection against polarity reversal
Overvoltage resistant up to 60 V DC (tested)
Semiconductor relay
[V DC] 30
[mA]
100
40
[Ω]
2
[μA]
10
[ms]
20
[ms]
Via optocoupler
Overvoltage resistant up to 60 V DC (tested)
37