Secure Router 4134 power and grounding
Secure Router 4134 power specifications
The following table describes the Secure Router 4134 chassis AC and DC power supply
units.
Table 4: Power supply specifications
Power supply
250 W AC
660 W AC
250 W DC
Caution:
Watch the power supply status LED for alerts when you hot swap a power supply unit.
Caution:
Ensure you use an appropriately rated AC power cord only. Do not use an extension cord.
Secure Router 4134 grounding specifications
The Secure Router 4134 ships with a grounding lug. You must connect your ground wire to
the lug and attach the lug to the chassis in the upper right-hand corner of the front panel. You
must attach the other end of the ground wire to the most convenient site ground point for your
installation. Use a maximum of 8 AWG grounding cable for the Secure Router 4134.
Important:
Avaya recommends that you install the chassis in the equipment rack before you install the
ground lug and the optional external interface modules.
Regulatory Information
Secure Router 2330/4134 power and grounding specifications
Input
100-240 V AC
+12 V DC at 250
Watts (20.83 Amp at
nominal voltage)
100-240 V AC
+12 V DC at 250
Watts (20.83 Amp at
nominal voltage)
-40 to -72 V DC
+12 V DC at 250
Watts (20.83 Amp at
nominal voltage)
Output to router
components
N/A
+54 V DC at 410
Watts (8.2 Amp at
+54 V DC) (isolated
from the +12 V DC
output)
N/A
PoE output
August 2013