Technical Data; Table 2: Technical Data - DAB EVOSTA2 Instrucciones Para La Instalación Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 138
5. APPLICATIONS
EVOSTA2, EVOSTA3 series circulators allow integrated adjustment of the differential pressure which enables
the circulator performance to be adapted to the actual requirements of the system. This determines
considerable energy saving, a greater possibility of control of the system, and reduced noise.
EVOSTA2, EVOSTA3 circulators are designed for the circulation of:
water in heating and conditioning systems.
water in industrial water circuits.
domestic water only for the versions with bronze pump body.
EVOSTA2, EVOSTA3 circulators are self-protected against:
Overloads
Lack of phase
Excess temperature
Over-voltage and under-voltage

6. TECHNICAL DATA

Supply voltage
Absorbed power
Maximum current
Grade of protection
Protection class
TF Class
Motor protector
Maximum environment temperature
Liquid temperature
Flow rate
Head
Maximum working pressure
Minimum working pressure
Lpa [dB(A)]
Designation index
(example)
Series name
Maximum head range (dm)
Centre distance (mm)
½" = 1"½ threaded outlets
= 1" threaded outlets
Standard (no ref.)
½"
X

Table 2: Technical data

= 1½" threaded outlets
= 1" threaded outlets
= bocche filettate da 2"
ENGLISH
1x230 V(+/-10%), 50/60 Hz
See electrical data plate
See electrical data plate
IPX5
F
TF 110
No external motor protector is needed
40 ºC
-10 ºC ÷ 110 ºC
See Table 3
See Table 3
1.0 Mpa – 10 bar
0.1 Mpa – 1 bar
≤ 43
EVOSTA
32
40-70/
130
½"
X

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Evosta3

Tabla de contenido