Descargar Imprimir esta página

Taking The Equipment Off; Technical Specification; Maintenance Schedule; Spare Parts - Sundstrom SR 500 Instrucciones De Uso

Ocultar thumbs Ver también para SR 500:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41

2.9 Taking the equipment off

Leave the polluted area before taking the equipment
off.
• Take off the head top.
• Switch off the fan.
• Release the belt and remove the fan unit.
After use, the equipment must be cleaned and
inspected. See 4. below.

3. Technical specification

Batteries
STD, Standard, 14.8 V, 2.2 Ah, lithium-ion.
HD, Heavy Duty, 14.8 V, 3.6 Ah, lithium-ion.
• The charging time for the STD battery is about 1.5 h.
• The charging time for the HD battery is about 2 h.
• The cycling life is about 500 full cycles.
Operating times
The operating times may vary with the temperature,
and the condition of the battery and filters.
The table below gives the expected operating times
under ideal conditions.
STD
HD
Filter
2,2 Ah 3,6 Ah
time
P3 (PAPR-P3)
P3 (PAPR-P3)
P3 (PAPR-P3)
A1BE2K1P3
(PAPR-A1BE2K1-P3)
A1BE2K1P3
(PAPR-A1BE2K1-P3)
A1BE2K1P3
(PAPR-A1BE2K1-P3)
Air flow rate
During normal operation, the air flow rate is at least
175 l/min, which is the manufacturer's recommended
minimum flow rate or MMDF. On boosted operation,
the air flow rate is at least 225 l/min.
Shelf life
The equipment has a shelf life of 5 years from the date
of manufacture. However, note that the battery must
be charged at least once a year.
Temperature range
• Storage temperature: from -20 to +40 °C at a
relative humidity below 90 %.
• Service temperature: from -10 to +55 °C at a
relative humidity below 90 %.
Materials
The plastic parts are marked with the material code.
4. Maintenance
The person who is responsible for cleaning and
maintenance of the equipment must have suitable
training and be well acquainted with work of this type.
Air flow
Expected
rate
operating
175 l/min
8h
175 l/min
13 h
225 l/min
8 h
175 l/min
5 h
175 l/min
8,5h
225 l/min
5 h
4.1 Cleaning
Sundström cleaning tissue SR 5226 that clean and
disinfect are recommended for daily care. If the
equipment is more heavily fouled, use a soft brush or
sponge moistened with a solution of water and
dishwashing detergent or the like. Rinse the
equipment and leave it to dry.
N.B. Never use a solvent for cleaning.
4.2 Storage
After cleaning, store the equipment in a dry and clean
place at room temperature. Avoid exposing it to direct
sunlight. The flow meter can be turned inside out and
can be used as a storage bag for the head top.

4.3 Maintenance schedule

The schedule below represents the minimum
requirements for maintenance routines in order to
ensure that the equipment will always be in functional
condition.
Before use
Visual inspection
Performance check
Cleaning
Change of fan gaskets

4.4 Spare parts

Always use genuine Sundström parts. Do not modify
the equipment. The use of non-genuine parts or
modification of the equipment may reduce the
protective function and put at risk the approvals
received by the product.
4.4.1 To change/charge the battery
See 2.5
4.4.2 To change the particle filters/
combined filters
Change the particle filters at the latest when they are
clogged. The fan senses when this has occurred and
provides a warning as described in 1.2 under the
heading Warning system/alarm signals. The gas filters
should preferably be changed in accordance with a
predetermined schedule. If no measurements are
made on site, the gas filters should be changed once
a week or more frequently if the pollutants can be
smelt or tasted in the head top.
Bear in mind that both filters/combined filters must be
changed at the same time and must be of the same
type and class. Proceed as follows:
• Switch off the fan unit.
• Unscrew the filter/combined filter.
• Release the filter holder. Fig. 24.
• Change the pre-filter in its holder. Clean as
necessary.
• To release the particle filter SR 510 from the
adapter, proceed as follows:
Grip the filter with one hand.
Place the thumb of the other hand on the
underside of the adapter at the semicircular
gap. Fig. 25.
Then prise out the filter. Fig. 26.
After use
Annually
39

Publicidad

loading