Commissioning

Commissioning the complete system

Pressurise your entire system slowly to avoid any uncontrolled movements.
S

Commissioning an individual unit

When adjusting the DSMI:
Warning
Risk of injury from rotating masses.
S Make sure that the DSMI is set into motion only
when the safety devices are fitted.
S Make sure that the swivel range of the DSMI
is safeguarded to prevent anyone from
reaching into the swivel range
no objects can get there (e.g. by means of an
individual protective screen).
Note
The mechanically set end position may change under operating pressure.
S Repeat the setting procedure under operating conditions.
Note
The swivel module will be destroyed by excessive mass moments of inertia.
S Make sure that the permitted mass moment of inertia is complied with for
the various operating modes.
The permissible mass moment of inertia during electronically controlled
operation exceeds the value of unthrottled use several times.