Setting the language
Turn the info button until "Lan-
guage" is displayed.
Press Info button.
Turn the info button until the de-
sired language is highlighted.
Press Info button.
Factory setting
The factory settings of all parameters
are restored.
Cleaning Programs
Parameters that are adjusted with the
grey Intelligent Key, are kept until an-
other setting is selected.
Turn the program selection switch
to the desired cleaning program.
Press the info button - the first ad-
justable parameter is displayed.
Press Info button - the set value
blinks.
Set the desired value by turning the
info button.
Confirm the changed setting by
pressing the Info button or wait till
the set value is automatically ac-
cepted after 10 seconds.
Select the next parameter by turn-
ing the Info button.
After all desired parameters have
been modified, turn the info button
until "Exit menu" is displayed.
Press the info button - you will exit
the menu.
Transport
DANGER
Risk of injury! When loading or unload-
ing the appliance, it may only be oper-
ated on gradients of max. 10% (Adv
15%). Drive slowly.
CAUTION
Risk of injury and damage! Observe
the weight of the appliance when you
transport it.
When transporting in vehicles, se-
cure the appliance according to the
guidelines from slipping and tipping
over.
With mounted D cleaning head
Remove brushes from the brush
head.
Storage
CAUTION
Risk of injury and damage! Note the
weight of the appliance in case of storage.
This appliance must only be stored
in interior rooms.
Select the storage site for the appli-
ance taking into consideration the per-
missible total weight of the appliance
in order not to impact its stability.
Maintenance and care
DANGER
Risk of injury! Before working on the
appliance, remove the Intelligent Key
and the mains plug of the charger.
Pull out the battery plug.
Drain and dispose of the dirt water
and the residual fresh water.
CAUTION
Risk of injury due to overrun of the suc-
tion turbine.
Suction turbine will continue to run for
a while after switch-off. Carry out main-
tenance tasks only after the suction
turbine has come to a halt.
Maintenance schedule
After the work
ATTENTION
Risk of damage. Do not sluice the ap-
pliance with water and do not use ag-
gressive detergents.
Drain off dirt water.
Clean protective turbine strainer.
Only with R cleaning head Remove
bulk waste container and empty it.
Clean the outside of the appliance
with a damp cloth which has been
soaked in mild detergent.
Clean the vacuum lips and the wip-
ing lips, check for wear and replace
if required.
Check the brushes for wear, re-
place if required.
Charge battery.
Monthly
During long operating pauses: Car-
ry out refill charging for the battery.
Check battery pole for oxidation;
brush it if required and lubricate it
using pole grease. Ensure that the
connection cable sits firmly.
Clean the seals between dirt water
reservoir and cover and check for
tightness, replace if required.
Check the acid density of the cells if
the batteries are not maintenance-
free batteries.
Clean the brush tunnel (only R
cleaning head)
13
-
EN
Remove the water distribution strip
from the cleaning head and clean
water canal (only R cleaning head).
Yearly
Have the prescribed inspection car-
ried out by the customer service.
Maintenance Works
Maintenance contract
To ensure a reliable operation of the
appliance maintenance contracts can
be concluded with the competent
Kärcher sales office.
Cleaning the protective turbine
strainer
Open the cover of the wastewater
reservoir.
Squeeze the locking hooks.
Pull off the float.
Turn the protective turbine strainer
in a counter-clockwise direction.
Remove protective turbine strainer.
Rinse dirt off the protective turbine
strainer with water.
Reattach protective turbine strain-
er.
Attach float.
Replacing the vacuum lips
Remove the vacuum bar.
Unscrew the star grips.
Remove the plastic parts.
Remove the vacuum lips.
Insert new vacuum lips.
Insert the plastic parts.
Screw in and tighten the star grips.
15