It is not possible to acknowledge a critical error. The device must be switched off and on. If the error persists, contact
your ABB Jokab Safety representative.
2TLC172298M0201
2015-09-15
Error mode
Microprocessor error.
(critical)
OSSD outputs off.
Optical error.
Error mode
OSSD outputs off.
EDM error.
Error mode
OSSD outputs off.
Override sequence error,
OSSD OFF
OSSD outputs off
Error mode
Dip switch error,
OSSD outputs off
(critical)
Internal and external lamp
Error mode
error, OSSD outputs off
Power supply error.
AOPD OFF
OSSD outputs off.
Turn AOPD off and on. If the error
persists, contact your
ABB Jokab Safety representative.
Acknowledge the error. If the error
persists, contact your
ABB Jokab Safety representative.
Check the wiring and the
connections of EDM SELECTION
and EDM as well as the time
sequence (see the Time chart in the
instruction
Acknowledge the error.
If the error persists, contact your
ABB Jokab Safety representative.
Check the time sequence of the
Override function (see the Time
chart in the instruction manual).
If the error persists, contact your
ABB Jokab Safety representative
Check the settings of the dip-
switches and turn the AOPD on and
off.
If the error persists, contact your
ABB Jokab Safety representative.
Check the connection of the external
lamp and acknowledge. If the error
persists, contact your
ABB Jokab Safety representative
Check the wiring and connections of
the power supply. Check that its value
is within the allowed range.
If the error persists, contact your
ABB Jokab Safety representative.