8 Putting out of operation

7.1 Welding process

8 Putting out of operation

9 Maintenance and cleaning

EN - 18
• Setting of the maximum main flow.
1 Open the shielding gas cylinder.
2 Switch on the power source.
3 Ignite the pilot arc.
The high-frequency ignition aid switches off automatically after igniting the arc.
4 Hold the welding torch above the workpiece in close proximity to it.
Maintain a distance of about 5 mm between the workpiece and the gas
nozzle.
5 Actuate the switching element on the handle and ignite the main arc.
6 Press the powder start key.
7 Start the welding process.
1 Switch off the powder delivery, main current and pilot current.
2 Switch off the power source.
3 Close the shut-off valves for the gas supply.
Regular cleaning, however, is a prerequisite for a long life and a trouble-free
operation.
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance,
servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Close the gas supply.
• Disconnect the mains plug.
DANGER

Electric shock

Dangerous voltage due to defective cables.
• Check that all live cables and connections are properly installed.
• Replace any damaged, deformed or worn parts.
®