Risk Of Burns - Abicor Binzel ABIPLAS WELD 100 POWDER W Instructivo De Servicio

Ocultar thumbs Ver también para ABIPLAS WELD 100 POWDER W:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

®
ABIPLAS
WELD 100/150 POWDER W
7 Operation
DANGER
Shortness of breath and poisoning caused by inhaling
phosgene gas
When welding workpieces that have been degreased with chlorinated
solvents phosgene gas is formed.
• Do not inhale fumes and vapours.
• Ensure a sufficient supply of fresh air.
• Rinse workpieces with clean water prior to welding.
• Do not place degreasing baths containing chlorine in the vicinity of the
welding area.
DANGER

Risk of burns

During welding activities, sparks, glowing workpieces or hot slag can
produce flames.
• Check the work area for flashpoints.
• Provide suitable fire extinguishing equipment at the workstation.
• Allow workpieces to cool down after welding.
• Prior to performing welding work, properly fasten the ground clamp to
the workpiece or the welding table.
WARNING
Arc eye
The arc produced for cutting can damage the eyes.
• Wear your personal protective equipment.
• Check the personal protective equipment before every cutting process.
NOTICE
• The system may only be operated by qualified personnel (in Germany
see TRBS 1203).
Prior to every use, check the following:
• Tight fit of the cable assembly connections on the power source, powder
delivery unit, gas supply and coolant recirculator.
• Equipment parts on the welding torch.
• Function of the coolant recirculator.
• Correct flow of the three process gases.
7 Operation
EN - 17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Abiplas weld 150 powder w

Tabla de contenido