Installation
Mechanical Installation – Standard
Models
Mounting Bolt Installation for Standard
135 Pound Capacity and 250 Pound
Capacity Machines
High-strength 3/4-16 x 10 in. machinery anchors should
be embedded in 3500 psi reinforced concrete that is a
minimum of 6 in. thick. Refer to Figure 8 for the
mounting bolt layout for standard 135 pound capacity
models. Refer to Figure 9 for the mounting bolt layout
for standard 250 pound capacity models. (The front of
the washer-extractor is the bottom of the diagram.)
Refer to Figure 10 for detailed information regarding
the machinery anchor bolt that should be used.
12.81 in.
(324 mm)
36 in.
(914 mm)
(1691 mm)
12.31 in.
(311 mm)
3 in.
(76 mm)
Figure 8
22
62 in.
(1575 mm)
1.25 in.TYP
(32 mm)
61 in.
66.63 in.
(1549 mm)
3 in.
(76 mm)
56 in.
(1422 mm)
135
CFS213N
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
72 in.
(1829 mm)
20 in.
1.25 in. TYP
(508 mm)
(32 mm)
40.69 in.
(1034 mm)
77.5 in.
(1969 mm)
19.5 in.
(495 mm)
3 in.
(76 mm)
66 in.
(1676 mm)
250
Figure 9
1
6 in.
(152 mm)
6 in.
MIN
(152 mm)
MOUNTING BOLT DETAIL – STANDARD MODELS
1
Locknut
2
Base Frame
3
3/4-16 x 10 in. Dia. Bolt
4
Grout
5
Anchor Bolt
Figure 10
80 in.
(2037 mm)
3 in.
(76 mm)
CFS214N
2
3
4
5
CFS215N
F232102