2. Lift out the sear burner.
3. Locate the Natural gas orifice at the end of the valve.
4. Use 6 mm socket wrench or 6 mm nut driver to remove
the orifice. Replace with the Natural gas orifice
IMPORTANT: Check that the orifice is properly installed
inside of the valve.
5. Reinstall the sear burner. Make sure that the igniter is out of
the way to allow proper positioning of burner. Use Phillips
screwdriver to attach the mounting screws.
6. Use Phillips screwdriver to reattach the igniter and sear
burner plate.
7. Reinstall sear burner cover. Use Phillips screwdriver to attach
mounting screws.
A
A. Orifice
.
A
A. Orifice
Change the Side Burner Orifices
1. Remove the screw securing the igniter and the 2 side
burner screws.
2. Lift out the side burner.
3. Locate the Natural gas orifice at the end of the valve.
A
A. Orifice
19