3. Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of
the 20 lb LP gas fuel tank to secure.
B
A. Locking screw
B. Mounting hole
C. Bottom collar
5. Slide the drawer with the 20 lb LP gas fuel tank back into
the cabinet. Turn the tank tray locking bracket
counterclockwise 90° to tighten.
A. Tank tray locking bracket
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas supply
to the selected grill location in accordance with the National Fuel
Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local codes.
For conversion to Natural gas, the Natural Gas Conversion Kit
supplied with the grill (on some models) or the Natural Gas
Conversion Kit Part Number W10118098 must be used. See
"Assistance" section for information on ordering.
IMPOR TA NT: The gas installation must conform with local codes, or
in the absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54 - latest edition.
Follow instructions for converting to Natural gas in the "Gas
Conversions" section of this manual or the instructions supplied with
Natural Gas Conversion Kit Part Number 710-0003.
The gas supply line shall be equipped with an approved shutoff valve.
This valve should be located in the same area as the grill and should be
in a location that allows ease of opening and closing. Do not block
access to the shutoff valve. The valve is for turning on or shutting off gas
to the grill .
A
A. Gas supply line
B. Shutoff valve "open" position
C. To grill
8
A
C
A
B
C