AdjUSTMENT LIMIT SWITCH
1. Activate the door by pressing the appropriate buttons, and check it moves
in the correct direction and If necessary, reverse the movement direction
by modifying the phase sequence, adjusting the line wires upstream of
the main switch.
2. Carry the curtain in the closed position.
3. By means of a screwdriver, turn the "C" cam until the relative micro-switch
is triggered, (fig.20).
4. Carry out the same procedure for the opening limit switch: bring the
curtain to the open door position, and adjust cam "A".
5. Activate the automation to check the calibration and, if necessary, make
a further adjustment.