Snap-On EEWB331B Manual De Operador página 35

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Note: The selection is permanently acquired.
Code C3
Selecting unbalance readings in grammes or ounces
0 = Readings in grammes
1* = Readings in ounces
This mode can be transferred to the permanent memory.
Code C4
Compensation of residual unbalance, if any, in the
clamping means.
High precision measurement.
Every time the clamping means are substituted,
compensation must be deleted or carried out again with
the new means fi tted.
Resetting the operating state to 0 cancels the clamping
means compensation.
The compensation is also cancelled following:
- Balancer calibration or recalibration,
- Unbalance optimization,
- Balancer switch off.
Select Code C4
Select one of the following options:
0 =
Carry out compensation
1 =
Compensation completed
0 =
Switch off compensation again after the
measuring run.
Note: The present operating mode cannot be
transferred to the permanent memory.
Code C8
Selecting the limit (threshold) value for suppression of
minor unbalance readings in ounces, or grams. The
unit of measurement (oz or g) depends on the
Ounces:
Range 0.12 to 0.71 oz
Factory-adjusted to 0.18* oz
Select another limit, e. g.: 0.50 oz
Select Code C8
• Set the value 0.50
• Press ENTER
Grams:
Range 3.50 to 20.0 g
Factory-adjusted to 5.0* g
Select another limit, e. g.: 5.50 g
• Select Code C8
• Set the value 5.50
• Press ENTER
Note: The selection is permanently acquired.
Code C11
Main shaft stop position.
The positioning brake stops the main shaft close to the
correction position by initiating pulsing braking.
The positioning brake is activated after switch on and
after a measuring run has been carried out and found
an unbalance greater than the limit value.
• Select Code C11
• Select one of the following options:
0 = No positioning brake after measuring run.
1*= Positioning brake after measuring run for left plane.
2 = Position brake after measuring run for right plane.
Note: The selection is permanently acquired.
Code C12
Measuring spin counter.
Example: 222,123 measuring runs completed:
• Select Code C12
• Select one of the following options:
1 = Total number of measuring runs completed
2 = Total number of measuring runs where balancing
was successfully completed, indicated by OK
3 = Total number of optimizations or minimizations
4 = Total number of measuring runs in Service mode
5 = Total number measuring runs since last
calibration
Every measuring run completed is saved. Maximum
count is 999,999 measuring runs. Once this number is
reached, the counter is reset to zero. The information
is primarily useful for statistical purposes, for example,
setting.
to monitor the endurance of faulty parts, or monthly
(yearly) use of the machine, etc. The measuring
runs performed while the machine is switched on are
transferred to the permanent memory and added when
it is switched off.
Note: The total counter (option 1) cannot be deleted.
Code C14
Readjustment of the machine by the operator
See instruction on chapter 7.0 of this manual.
EEWB331B
35

Publicidad

Tabla de contenido
loading

Tabla de contenido