4.5.3 Manual Parameter Entry

In the event of automatic gauge failure, the parameter
values can be input manually. See manual entry of rim
width in the previous paragraph.
Figure 24a
D
W
O
Figure 24b

4.5.3.1 Manual Rim Diameter Entry

- Select the Manual Diameter button. Read the rim
diameter marked on the sidewall of the tire (Figure 24a
and 24b). Press the Diameter Button (D) and enter the
measured rim diameter by selecting the +/- keys until
the desired value appears in the display.
Figure 24c

4.5.3.2 Manual Distance Entry

- Move the distance gauge arm to touch the inner edge
of the wheel where weights are to be placed and observe
the reading on the scale of the distance gauge (See
arrow, Fig.24c). Press manual Wheel Offset button (O)
followed by selecting the +/- keys until value is displayed
in the display window.
NOTE: The parameter arm must be in the Home rest
position when the balancer is powered up. This estab-
lishes the arm starting position.
4.6

Easy Alu FUNCTION

The Easy Alu function automatically recognizes the
desired weight location by placing the SAPE arm in
the correct locations.
Note: Alu Modes 4 and 5 are not operable in the Easy
Alu function. They require manual setting.
4.6.1
Automatic rim dimension reading
and setting and Alu Mode
Preparations:
— Compensation run carried out, if necessary.
— Wheel correctly clamped.
Important: The OK indication and recommendation
for optimization, as well as the optimization procedure
itself, will only be accurate if the rim width is correctly
entered (Manual Input).
Automatic rim distance and diameter reading with
an internal gauge arm
— Move the internal gauge arm into position on the
rim to select the initial weight application position
(internal rim side). Keep it in this position until an
audible signal is heard.
Figure 25
Only for Alu2P and Alu3P (Fig. 25):
— Position and hold the internal gauge in the second
position on the rim to select the application position
on the right side of the rim.
Shortly afterwards the machine emits an audible
signal to indicate that the machine automatically
saves the weight application coordinates.
— Move the gauge to the idle position.
— For Alu2P and Alu3P you can start the spin.
— For all the other Alu, previously enter the rim Width.
At this point you can change the Alu mode suggested
by the machine, using the "Weight selection button".
Do this by pressing the key