16. OPERATION
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes
to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
A. D
S
:
ELAY
WITCH
When a blower speed is selected, press this switch to activate the delay function. The corresponding blower speed switch
will flash to indicate this function is activated. The blower will continue to operate for 5 minutes and will stop automatically.
To cancel the delay function, press the delay switch once again.
B. S
/S
/S
S
TART
TOP
PEED
ELECTION
Press the switch corresponding to the desired blower speed (from 1 for low speed to 4 for high speed). The chosen switch
will light. To turn off the blower, press once more on the corresponding blower speed switch; the switch light will shut off.
NOTE: When blower is off, pressing on blower speed 1 switch will cause the blower to start on high speed for a very
short lapse of time, and then resume on speed 1.
C. M
OFF/F
M
ASTER
ILTER
i. To turn off the blower and the light simultaneously, press this switch once.
ii. After 25 hours of operation, this switch will light to indicate the filters and the blower wheel(s) need to be cleaned in
order to maintain efficient operation of the unit. The switch light will stay on until the function is reset by pressing this
switch for 3 seconds.
iii. The light indicator is used for the Heat Sentry function as well.
H
S
: When an excessively high temperature is detected, the detector takes control over the blower and
EAT
ENTRY
set it on speed 3; its switch light comes on and the Heat Sentry switch flashes.
The blower will remain on until the heat is back to normal, it then returns to the speed previously selected.
The Heat Sentry can start the blower even if the hood is turned off. When this situation occurs, it is impossible
to turn the blower off using the push buttons. If you must stop the blower, do it from the main electrical panel.
NOTE: In a case of range top grease fire (temperature exceeding 90°C), the Heat Sentry will be deactivated to prevent fire
propagation.
D. L
S
:
IGHT
WITCH
This switch allows three different lighting levels according to your needs. Press once for nightlight, twice for normal or three
times to obtain full intensity. To shut off the lights without turning off the blower, press once more.
17. WIRING DIAGRAM
120 VAC
COLOR CODE
BLK
BLU
BRN
GRN
GRY
ORG
RED
WHT
YEL
HE0111A
HC0023
A
S
:
WITCHES
/H
S
AINTENANCE
EAT
ENTRY
J3
YEL
J2
J1
YEL
WHT
J9
BLK
J10
WHT
WHT
BRN
GRN
BLK
M
ORG
GRY
BLACK
WHT
BLUE
BLU
BROWN
GREEN
BRN
GREY
BLK
ORANGE
M
RED
WHITE
ORG
YELLOW
GRY
WHT
BLU
B
™ (T
F
S
RIPLE
UNCTION
WITCH
WARNING
!
T1
WHT
J8
WHT
YEL
WHT
BLK
YEL
BLK
WHT
ORG
RED
BLK
WHT
WHT
J6
1
2
3
4
5
RED
RED
ORG
BLK
WHT
J7
BLU
1
2
3
4
5
- 11 -
C
D
):
1
RED
2
3
BLK
J4
FAN SPEED AND
1
LIGHT CONTROL
2
3
J5
5
4
3
2
BLU
1
J15
J11
BLU
To Make-up Air
BLU
J12