Immergas EOLO Star Manual De Instrucciones página 266

Ocultar thumbs Ver también para EOLO Star:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
maximum Resistance Factor equal to 100. The maximum permissible Re-
sistance Factor corresponds to the resistance detected with the maximum
ES
permissible pipe length with each type of Terminal Kit installed. This
information enables calculations for verifying the possibility of various
configurations of fume exhaust systems.
PT
Diaphragm installation. To ensure correct boiler operation, a diaphragm
(see figure) must be installed on the outlet of the sealed chamber before the
intake and exhaust duct. The choice of a suitable diaphragm depends on
the type of duct used and its maximum length: calculations can be made
GR
using the values in the following tables:
DIAPHRAGM
PL
TR
CZ
CS
N.B.: Diaphragms are supplied standard with the boiler.
SI
HU
DIAPHRAGM
RU
Ø 39
Ø 41.5
RO
IE
DIAPHRAGM
Ø 39
Ø 41.5
DIAPHRAGM
Ø 39
Ø 41.5
DIAPHRAGM
Ø 39
Ø 41.5
* The values for maximum length are considered with 1 metre of exhaust
pipe and the remaining on intake.
264
Duct length in metres
Ø 60/100 horizontal
From 0 to 1
Over 1
Duct length in metres
Ø 60/100 vertical
From 0 to 2.7
Over 2.7
*Length in metres
Ø 80 horizontal pipe
with two bends
From 0 to 20
Over 20
*Length in metres
Ø 80 vertical pipe
without bends
From 0 to 25
Over 25
DIAPHRAGM
Ø 39
Ø 41.5
DIAPHRAGM
Ø 39
Ø 41.5
Positioning of double lip seals. For correct positioning of lip seals on
elbows and extensions, follow the assembly direction given in the figure.
Duct length in metres
Ø 80/125 horizontal
From 0 to 1.9
Over 1.9
Duct length in metres
Ø 80/125 vertical
From 0 to 6.8
Over 6.8

Publicidad

Tabla de contenido
loading

Tabla de contenido